Specification
Medium |
Low viscosity, no strong corrosive, purity liquid |
Pipe Size (mm) |
Thread: DN4-DN50 Flange: DN15-DN200 |
Accuracy |
±1%R, ±0.5%R, ±0.2%R, |
Range Ratio |
1:10, 1:15,1:20 |
Sensor Material |
SS304, SS316(L) |
Medium Temp. |
-20℃-+80℃ |
Environment Temp. |
-20℃-+60℃ |
Relative Humidity |
5%~90% |
Atmospheric Pressure |
86KPa~106KPa |
Power Supply |
24(1±15%)VDC, Ripple Wave≤±1% (4-20mA, pulse, rs485 etc.) One group 3.0V10AH battery (voltage 2.0V~3.0V) |
Output |
Pulse, 4-20mA, RS485(MODBUS-RTU). HART etc. |
Flange Standard |
GB/T9113-2000, DIN, ANSI, JIS etc. for option |
Thread Standard |
G1/2, 1/2NPT or customized |
Electrical Interface |
M20*1.5 or customized |
Ingress Protection |
IP65 or customized |
Explosion-Proof |
ExdIICT6 Gb |
Diameter (MM) |
Standard Flow Range |
Extended Flow Range |
Connection and Pressure |
Q min (m3/h) |
Max Pressure Loss(KPa) |
4 |
0.04-0.25 |
0.04-0.4 |
Thread, 6.3MPa |
0.02 |
120 |
6 |
0.1~0.6 |
0.06~0.6 |
Thread, 6.3MPa |
0.05 |
80 |
10 |
0.2~1.2 |
0.15~1.5 |
Thread, 6.3MPa |
0.07 |
50 |
15 |
0.6~3.6 |
0.5~5 |
Thread, 6.3MPa |
0.35 |
35 |
20 |
0.8~8 |
0.45~9. |
Thread, 6.3MPa |
0.3 |
35 |
25 |
1~10 |
0.5~10 |
Thread, 6.3MPa |
0.4 |
35 |
32 |
1.5~15 |
0.8~15 |
Thread, 6.3MPa |
0.6 |
35 |
40 |
2~20 |
1~20 |
Thread, 6.3MPa |
0.6 |
35 |
50 |
4~40 |
2~40 |
Flange, 4.0MPa |
1 |
35 |
65 |
7~70 |
5~70 |
Flange, 1.6MPa |
4 |
25 |
80 |
10~100 |
7~100 |
Flange, 1.6MPa |
5 |
25 |
100 |
20~200 |
10~200 |
Flange, 1.6MPa |
8 |
25 |
125 |
25~250 |
13~250 |
Flange, 1.6MPa |
10 |
25 |
150 |
30~300 |
15~300 |
Flange, 1.6MPa |
12 |
25 |
200 |
60~800 |
40~800 |
Flange, 1.6MPa |
20 |
25 |
Accuracy |
±0.5% |
±1% |
PF300 |
Liquid Turbine Flow Meter | |||||||
Model |
A1 |
24VDC,Pulse output, Without display | ||||||
A2 |
24VDC,4-20mA,With display | |||||||
A3 |
Double power, with display, RS485/4-20mA/pulse | |||||||
Pipe Size |
DN25-DN400 (MM) | |||||||
Connection |
F |
Flange | ||||||
T |
Thread | |||||||
Flow Range |
S1 |
Standard Range | ||||||
S2 |
Extended Range | |||||||
Body Material |
M1 |
SS304 | ||||||
M2 |
SS316 | |||||||
Accuracy |
A1 |
±1%R | ||||||
A2 |
±0.5%R | |||||||
A3 |
±0.2%R | |||||||
Impeller Material |
S |
2Cr13 | ||||||
L |
Diphasic steel impeller |